Position the 2-way valve inside the water heater to EXT. Default recirculation schedule is every 30 minutes if a 9F degree drop is sensed. The control is recirculation only. We might be able to do something about it. By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. Personally I would start by setting parameter 12 to 1 minute. Am I reading this excellent web page & comments correctly? Efficient, durable and high-performance products for any commercial application. For a better experience, please enable JavaScript in your browser before proceeding. I am still seeing wonkey things happening but the schedule seems to work now. Part No. The house is set up with recirculation, though I am not sure where in the house the "T" on the system is located. is this recirculation pump just recently installed? Then disconnected for unknown reasons. Let's check the dip switch settings too. How To Use Recirculation Mode On Navien Water Heater? I set my first three dip switch settings to ON, ON, OFF which is what the manual said the settings are supposed to be for intelligent pre-heating. You are right. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. For the Navilink and recirculation to work: May 14 2022. Thanks for the comments folks. A VPN connection will not be established. Strong signal. 22 Installing the Water Heater CAUTION Do not remove recirculation cap Internal Recirculation Mode The following diagram shows the internal . I agree. Internal will keep open the same valves but also use the internal pump as set, and not rely on any external pump. Water heater without tanks, also called instant water heaters heat water immediately upon request. I have even had to swap out control and front panel boards to get the function to work, but they broke that with an app update. . It just will not connect. Quote. You can find this valve inside the water heater. I call about every 6 months to get any updates on the issue they know nothing about every time. I love everything about the hardware. Displays temperature and water flow rate. Our fancy NPE-240A2 was installed yesterday with Navilink. This may eliminate the waiting for hot water depending on installation method. I'll have to look at the manual again, but the one I have does detail dip switch settings. If you can post a picture of your setup it would really help. You can find one on the PCB and the other one on the front panel. On-demand takes a bit longer to heat up, but oh well. PreReqs: RACADM ktpass Powershell 3.0 (2.0 probably works too, but I was using 3.0@ the time) Your root CA's cert This is so it AD Authentication can be setup Solution: It's not a complete solution, but hopefully it'll help you get started in your own endeavors. Apparently this information is only for a licensed contractor..sigh. This removes the need to purchase an additional circulator for the heating system. So what's going on here? Navien NPE-240A dip switch settings help please I just got finished getting my Navien NPE-240A tankless installed. It may not run the entire time but it does run. It's unfortunate he's not around to explain all this to you. Set the position of the 2-way valve, which you can find inside the water heater. I have a Navien NPE-240A tankless heater, . (Measure Guideline : Transitioning to a Tankless Water heater, DOE, Sept.2012). Just want to say thanks for everyone that has commented thus far. You are using an out of date browser. Thanks for your inquiry. Today I opened the front panel and saw that all the dip switches were set to off. Yes, I know. Using, Summary: NSX-T loses synch w/ vCenter inventory, but statuses don't appear to show an issue. Generally, you should flush a Navien Tankless Water Heater once a year. Colector ReadyLink Hoja De Especificaciones Espanol (USA & Can NPE Guia De Conversion De Gas (USA & Canada), NPE Guia De Instalacion Rapida Espanol (USA & Canada), Navien-NPE-Series-CSI 3-Part Formatted Specifications, Ready-Link Manifold 2BB Submittal Package, Ready-Link Manifold 2SS Submittal Package, Ready-Link Manifold 3SS Submittal Package, Ready-Link Manifold 4BB Submittal Package, Ready-Link Manifold 4SS Submittal Package. Tech support is clueless. They are: If you want to select or activate any of the two recirculation modes, you must do two things: You can enjoy several benefits if you activate the recirculation mode. PFFW-001, NaviCirc Kit: 30022965A. It looks like you're using an ad blocker. My pump seems to run every time I need hot water. We might be able to do something about it. Are you sure it is the pump running and not the blower for the heat exchanger? Set the 2-way valve to INT. So disabling and enabling the schedule does not work as a workaround to the hot button feature not showing up except for the fact that when enabled it will find that the reservoir temp is lower than it should be and begin to heat it, which then in turn will allow it to start to recirculate again (not time saving or water saving at all). It may not display this or other websites correctly. If any particular ad is your REASON for blocking ads, please let us know. Right now I have it on recirculate all day long, which gives me instant hot water, but wastes a lot of energy. Navien Recirculation Settings have a lot of advantages. Factory Setting of DIP Switch. Connect the water supply. Im fairly certain this is the case. Could someone please confirm that I should indeed have well pump "ON"? Completing the Install. Thanks. It gives me the option to 'control' and create a weekly schedule. Part No. We have a Navien NR-240A installed in new construction in 2012. Sign In Upload. I have even turned off the scheduling function cause it's wasteful if I'm not around and forget to turn it off. Press J to jump to the feed. Disabling schedules simply disables "recirculation", the function that keeps hot water hot in the plumbing for 'instant hot water'. This gives users hot water when they need it, saving water and money. For a better experience, please enable JavaScript in your browser before proceeding. Operation. Cause is unknown. Thanks for the summary and the reply to my question as well as the others. Also, you can use the Navien Intelligent Preheating feature. Summary: I was looking to automate configuration of iDRAC's (Dell Remote Admin Console) synonymous w/ iLOM and many other acronyms. Brochures English Commercial Solutions Brochure H2Air Brochure NPE Contractor Brochure NaviLink Consumer Brochure Spanish - MX H2Air Brochure Sistema Colector ReadyLink NPE Catalogo Manuals English I tried purging the line - Answered by a verified Plumber . Summary: I started running into issue utilizing Cisco AnyConnect on my Mac basically complaining about not able to overwrite IP forwarding tables. Zsoldier, he dip switches there dont get into the real detail of the programming. Thanks for any insight you can provide. Protect the water supply and water heating equipment with eco-friendly water treatment solutions. It was totally worth it, here is why and how to set it up. Specifically, you can find a number of dip switches on these two locations. I've learned some things myself. Read Also: Navien Tankless Water Heater Post Purge Navien Tankless Water Heater Standby Mode Eric Alvarez The Navilink app is "meh" at best and their documentation of the "smart" features is nonsensical. This is how to set up Navien Tankless water heater for recirculation in Residential applications. Deactivate Circulator Timer and Periods. Navien Recirculation Settings have a lot of advantages. If any particular ad is your REASON for blocking ads, please let us know. Parameter access and and parameters are listed here in section 6.5 page 65. I expect that would have some positive effect on the time to deliver hot water, even if it is small. This light stays on for about 15 seconds, turns off for about 15 seconds, and then blinks 36 times. But would like to have the 'instant button' in the app that I could push in the evening, where it would recirculate the water for me on demand, and then five min later I can take a hot shower. There is always an interval between when water is called for and the start of the burner. 6. Navien Now Doing Business in Canada as Navien Canada, Inc. Navien Begins Shipping PeakFlowC Commercial Scale Prevention Systems. Disabling schedules simply disables "recirculation", the function that keeps hot water hot in the plumbing for 'instant hot water'. Dave, if you could enlighten me (other users) on what you had to do to get scheduling to work that would be great. I was reading the directions, and it wants me to set the Heater to External recirculation. Im also interested in food and travel. Hope this helps. The update is not perfect, but seems to be much more user friendly interface. The Intelligent preheating on Navien Water Heater is a self-learning process that you can enable by turning on the DIP switch on the front panel. Looks fine, Y U NO WORK!? This chapter will walk you through the step-by-step guide to let you learn how to use the recirculation mode. I agree with Spacecowboy-- The information I have refers to external recirculation with cold water line return, but I expect the settings would be the same with a dedicated return line. Just want to confirm. that fan will come on when water is called for and go off a bit after the call has stopped. To make sure that the model has this feature, you simply need to check to see if there is an 'A' at the end of the model number. I just got off the phone with a "Senior" support specialist. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. I too have the NPE-240A, and this is what was explained to me. They understand systems like this and can help you choose the right pump and control that only recirculates when you tell it to. Efficient and earth-friendly products designed for any size home. For example, it will boost up the energy consumption because the unit operates to maintain the water temperature within the circulation loop. Im a Principal Software Engineer in Microsoft's Azure Dedicated group living in Atlanta, Georgia. The app will not connect to my wifi. Thanks again Mate! Navien 240A Recirculation Settings. My water is well water so I am assuming this is correct. The enable/disable work around for a hot button really speaks to the fact that they could just make an app based digital hot button alone-- with a timer better yet to resume the normal schedule. At the push of a button, Navien's HotButton accessory activates the internal recirculation pump and gas-fired burner to heat up the water in the supply lines. Thanks in advance for your time. It will reduce the energy consumption and deliver you the best heating efficiency. My NaviLink was working just fine for about2 months. Then if that doesn't work, I would keep it at 1 minute, and then set 14 to 1 minute, and I would also try 14 at its max. Thanks. Naviens patented ComfortFlow system is the first to include a buffer tank, recirculation pump and fine-tuned controls into a tankless water heater, resolving the cold-water sandwich effect* and issues of minimal flow rates commonly found in other tankless water heaters. Privacy Policy. 800-556-7556 or see HarryEklof.comFull Naivien information including dealer and Rep locators is available at www.navieninc.com Either you select the Internal Recirculation Mode or the External Recirculation Mode, both these modes has three common recirculation loops: However, the External Recirculation mode has an additional recirculation loop called HotButton, which takes it apart from Recirculation mode. Tech support was clueless. In reading the comments there seems to be confusing information as to whether the schedule button should be set to ENABLE or DISABLE. If you'd like to support the site, please allow ads. If you don't have external recirc pump dip 1 should be on. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. I just had an NPE240A2 professionally installed last week. If you want the heater to provide the cross over where the hot return and cold combine then set it to internal. High-efficiency condensing and non-condensing tankless water heaters offer endless hot water and reduce gas usage. Hot button documentation is super vague too. In particular I'd like to change the temperature at which it begins to recirculate, or the frequency of it. Designed for retrofit and new construction, the Navien H2Air Kit includes an add-on controller to integrate space heating and DHW between any NPE-A2 series tankless water heater and a hydronic air handler. Efficient, durable and high-performance products for any commercial application. Water Heater DIP Switch Settings. This Taco valve can even be cleaned easily. Since the app updated and removed the option to enable or disable the recirc and enable or disable the schedule, mine has not worked and defaults to every 30 mins recirc. Press either the Up and the Down button to switch between any of these recirculation settings: 3. 1. What I am finding now is if you call at 8am Eastern time you get New Jersey. You are incorrect. Also the unit needs to be set to utilize the recirculation feature. Attach the water supply to support recirculation. If you'd like to support the site, please allow ads. Hello, You might want to talk with the folks at ACT, 714-668-1200 www.gothotwater.com. The problem is that NSX-T doesn't see the new host and its link to the compute manager (vCenter) looks fine. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, PeakFlowE Installation, Operation and Maintenance Manual, Manual De Sistema Ventilacion Comun Espanol (USA & Canada). Internal Recirculation and make the selection by pressing the Ok button. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. PFFW-001, NaviCirc Kit: 30022965A. Using the internal pump to set up an external re circulation line through the cold water system as return with a Grundfos comfort valve at the last fixture in the line. 7. Nearly Instantaneous hot water can be achieved with a Navien tankless water heaters with a proper recirculation system but is dependant on the homes piping system.Please contact Harry Eklof \u0026 Associates for more information or to set up a training class for your company. External means you will be using a seperate pump, not the internal one inside the unit. My 6-year-old NR-240A NR-240A weekend with E038. I, recently had a Navien NPE-240A unit installed. Eventually, I want to run a return line from the kitchen area back to the hot water heater and that should significantly reduce the delivery time, since all the faucets feed off the line that leads to the kitchen. *DIP Switches need to be set properly as well. I'm going to install the Navicirc tomorrow when i have a few minutes. Called Navien to find out what/if the dip switch settings should be when using the controller and they will not give them to me as the homeowner. How often should you flush a Navien tankless water heater? What I have found to keep it easy for understanding the schedule enable/disable on the appis to add the letter "d" at the end of the word being displayed. "If you can't explain it simply, you don't understand it well enough". Hot water is still on-demand when in a 'off-schedule' mode, but may take longer for hot water to dispense because the plumbing is cold. Gas. I had a dedicated external recirculation line installed to use with the Navien internal pump. BTW it connect to my phone through the app but then doesn't connect to home wifi and doesn't ask for my password. Optional Wi-Fi remote control systems Thanks. I also bought a Navicirc. I would make my back steps half of the known good/bad settings to speed up the search process. PreReqs: Homebrew Installing OpenConnect: Launch MacOS Terminal brew install openconnect Getting VPN IP's/DNS Endpoints from AnyConnect: The information is typically located in your profile xml files located here: /opt/cisco/anyconnect/profile/somethingsomething.xml In the xml file, you are looking for "typicallyaDNSName.com" entry. So you could restart the cm-inventory service till you are blue in the face and get nowhere be. Sorry just saw this. Click here to see downloads for other products. Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. 8. They stated that the "Default" re-circulation schedule is every 30 minutes if it senses a 9 degree drop. It allows you to choose the time in 30 minutes intervals. Just had installed a Navien 240a. What I am going to discuss in this article is-. Learn more about our products for home owners. I also wanted to enable domain authentication in a somewhat secure manner. How to use the recirculation modes on a Navien Water Heater? There is 4 options (6 technically, but the 5th and 6th dont apply). External with internal pump. Hi therejust curious since I was considering a Navien 240A. a faucet is open) and no recirculation is occuring? Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. I just want to make sure my understanding is correct. 0:00 / 4:21 Troubleshooting Navien NPE-240A Internal Recirculation Pump RCGooner2002 240 subscribers Subscribe 553 122K views 5 years ago Recirculation pump was not providing faster hot. Internal with external pump. Error Code E046 It indicates that there is something wrong with limit control. If so, what size/model is it? Yierd! Then I searched and discovered your posting. Is that correct? The Navien cascading system also balances out the workload of each unit for longer life. Can anyone lend some guidance as to what the recommended dip switch setting should be? Error Code E047 This appears to affect NSX-T 2.5 and 2.5.1. 2. Hey there, Im Chris. The NaviLink system attaches easily to any new or existing* Navien tankless water heater, combiboiler and boiler. That's it, there is no other response from the unit. This seems relatively new for Navien and is in a recent Navien technical bulletin from 04/18/16. Similar to the Navien NR-210A, the NR-240A is a tankless water heater with a built-in circulation pump and buffer tank, except that this model delivers 11 gallons per minute at 45oF rise. But you may need to flush the unit every six months if you live in a hard water area or operate the unit at a higher temperature setting. Navien's NR-180A, NR-210A, NR-240A, NPE-180A, NPE-210A and NPE-240A models come with the ComfortFlow System. Condensing combi-boilers deliver high-efficiency endless hot water and space heating in one compact unit. If the hot button is not engaged, or a schedule is not specified and enabled in the app then the water heater simply will not re-circulate. My home is long and used to have two water heaters, one on either side of the house. MacOS: AnyConnect VPN client was unable to successfully verify the IP forwarding table modifications. Their are lots of ways your system may be piped. dip one off, dip 2 on, everything else off (down is off). Hard to really know if you need button or not. Naviens new backlit EZNav control panel uses simple text and icons to make set up, operation status and troubleshooting faster and easier than ever before. Create an account to follow your favorite communities and start taking part in conversations. 57. Error Code E046 There is something wrong with limit control. So when you request hot water, its going to start the pumps to make sure that water stays heated as it passes through. Once you turn that DIP switch, the water heater software will monitor the flow demands over a 7 day cycle and recirculate the water from the following week based on water usage. Replacing one NPE for two 90 gallon tanks ( one dead and one likely to die) was a cost savings even though the NPE and recirc is expensive. Navien 30015307A Circulation Pump, NCB-E Models OEM PART $272.95 In Stock FREE SHIPPING Navien 30002583A High Limit Switch, OEM PART $18.85 In Stock FREE SHIPPING Navien HotButton Recirc Pump Control for NPE-A Series, PZZZ-00046 $115.45 In Stock FREE SHIPPING NAVIEN 30014189B NHB FLAME ROD ASSEMBLY, OEM Part $31.38 In Stock FREE SHIPPING